JK BMS 1A 2A 5A Balance Current 8S 12S 13S 14S 16S 17S 20S 24S Smart JK Bms 60A 80A 100A 150A 200A 600A Lifepo4 Li-Ion Battery

In Stock

$79.98$241.19

Product Description

JK BMS 1A 2A 5A Balance Current 8S 12S 13S 14S 16S 17S 20S 24S Smart JK Bms 60A 80A 100A 150A 200A 600A Lifepo4 Li-Ion Battery

  • Brand Name: HANKZOR
  • Accessory Type: Charger Accessories
  • Origin: CN(Origin)
  • Model Number: BMS
  • Certification: CE
  • Certification: FCC
  • Certification: RoHS
  • Applications: lithium battery rated
  • Battery series: 12S-24S
  • Overcharge protection: YES
  • Over discharge voltage: YES
  • Short circuit protection: YES
  • Balance function: YES
  • Bluetooth: YES
  • GPS: According to the Customer need
  • RS-485: YES
  • CAN: According to the Customer need
  • Accessory: Wire cable is free

Orders after 2022.05.01 will be equipped with a free active switch.

Package Includes:

  • BMS{Bluetooth bulit-in(with P- and B- 7AWG 13cm*2)}
  • Temperature sensor(40cm)
  • Balance Wires(75cm)
  • Active Switch(15cm)
  • Heating cable(Only  for B2A8S20P-H)

NOTE:

  • Due to the different voltage ranges supported, among the accessories of B1A8S20P/B2A8S20P, RS485, LCD and other BMS are not common. Power Board is the same version. Please choose to buy them carefully.
  • Internal/2 External Temperature Sensors (Detect battery temperature)
  • LCD and RS485 interfaces are configured by default
     

Bluetooth link for Phone-JIKONG BMS

Download App for IOS : Search (JIKONG BMS) in the APP STORE

Download App for Andriod : https://www.pgyer.com/Cfq3

If you need to use BMS in parallel, Fast Class T Fuse must be added to each battery pack. Or discharge diode (high power diode selected according to load) Provide a diagram (thanks to members of diysolarforum for sharing).

 




NOTE:

①:Temperature sensor
②:RS485 interface(At present, all JK BMS are configured with RS485 function by default)
③:LCD interface(At present, all JK BMS are configured with LCD interface by default)(Except of  JK-BD4A17S4P)
④:Heat Function interface(At present, the heating function customized by customers can be accepted)
⑤:CANBUS interface ( Needs customized)





NOTICE:

Protection (Current Sensor Anomaly)
This problem exists when the inverter is used because the current direction is uncertain, The alarm will be displayed. It does not affect the normal use of BMS. This kind of alarm will appear when the sun is not big or small because, at this time, the battery fluctuates frequently between charging and discharging, and there are uncertain factors, so this problem occurs.

A pure sine wave inverter does not draw a constant current. The current from the battery follows a sine wave shape. It ramps from zero current up to peak current in 1/4 of a cycle. The peak current is actually about 40% more than the average current. Then the current will ramp back down to zero at the 1/2 cycle time. At this point, the inverter reverses polarity, and ramps the current back up again, hitting the peak at the 3/4 cycle time. The battery current is positive again, and the inversion happens in the inverter circuit. The current ramps down back to zero again at the end of the cycle. The process then repeats for every cycle.

If you measure with an averaging meter, you will just see a fairly steady current that should be close to the true RMS current. I use a True RMS Fluke meter, and it is able to give a very accurate reading on this odd waveform. The current reading in the BMS just measures the voltage across a shunt resistor. This reading is only taken periodically, and it is not synced with the changing current from the inverter. It might take a reading at zero current, or at the peak current, but most likely, it will fall somewhere in between. Due to the shape of the wave, the reading tends to bounce a bit above and below the true RMS current. It is not perfect, but over the long term, it is “good enough” for the BMS to calculate the amp hours charged in or discharged out of the battery. This works because if you average the readings over a full hour, the high and low readings will average.

There is not a simple fix for the short term